newsbjtp

Mga Tagubilin sa Xingtongli Rectifier

1. Front panel back panel

Xingtongli-Rectifier-Mga Tagubilin

1-AC Input Switch (Single Phase-1P, Three Phase-3P) para Kontrolin ang AC Power Supply

2-Time Relay (User Opsyonal), Timing Control

3-Output Voltage Display Header (V)

4-Output Kasalukuyang Display Header (A)

5-Constant Current/Constant Voltage Switch, Piliin ang Operating Mode, Hindi Pinahihintulutang Magbago Habang Operasyon ng Device

6-Power Output Switch (ON/OFF), Control Power Operation o Standby

7-Power Operation Status Indicator Light (Berde: Normal na Power Operation, Pula: Power Failure)

8-Power Output Adjustment Potentiometer

9-Pause Button para sa Time Relay (Karagdagang Time Relay)

10-Reset Button para sa Time Relay (Karagdagang Time Relay)

11/12-Output Terminals (Polarity bilang Minarkahan sa Power Supply Back Panel, Pula para sa Positibo, Itim para sa Negatibo)

13-AC Input Lines (Single Phase-Three Wire: LN-PE; Three Phase-Four Wire: A(U)-B(V)-C(W)-PE, o Three Phase-Five Wire: A(U) -B(V)-C(W)-N-PE)

14-Chassis Ground (PE)

15-Remote Control Line Output Terminal (Opsyonal para sa Uri ng Remote Control)

Local/Remote Control Type(Polarity Reverse)

Mga Tagubilin sa Xingtongli Rectifier

1 – Awtomatikong Changeover Time Relay (User Opsyonal), Naka-time na Kontrol

2 – Output Voltage Display Header (V)

3 – Output Kasalukuyang Display Header (A)

4 – Manu-manong Pagpasa/Baligtad na Switch

5 – Manu-mano/Awtomatikong Changeover Switch

6 – Constant Current/Constant Voltage Switch, Piliin ang Operating Mode; Hindi pinapayagan ang Constant Current sa Constant Voltage Conversion sa panahon ng pagpapatakbo ng device.

7 – Power Output Switch (ON/OFF), Control Power Supply Operation o Standby

8 – Power Output Adjustment Potentiometer

9 – Start Button para sa Automatic Changeover Time Relay (Katugma sa Time Relay)

10 – AC Input Switch (Single-Phase-1P, Three-Phase-3P), Kontrolin ang AC Power Supply

11 – I-reset ang Button para sa Awtomatikong Changeover Time Relay (Katugma sa Time Relay)

12 – Mga Linya ng Input ng AC (Single-Phase Three-Wire: LN-PE; Three-Phase Four-Wire: A(U)-B(V)-C(W)-PE, o Three-Phase Five-Wire: A (U)-B(V)-C(W)-N-PE)

13 – Chassis Ground (PE)

14, 15 – Mga Output Terminal (Polarity gaya ng ipinahiwatig sa back panel ng power supply, Pula para sa positibo, Itim para sa negatibo)

16 – External Control Box Lead (Pumili sa pagitan ng Remote Control Panel at Local Control Panel)

17 – Remote Analog Control Port (Opsyonal: Nangangailangan ng PLC Interface Board para sa power supply)

18 – Remote MODBUS Control Port (Opsyonal: Pumili sa pagitan ng Remote Analog Control at Remote MODBUS Control; Ang Remote MODBUS Control ay nangangailangan ng PLC o Microcontroller Control System para sa power supply)

19 – Power Supply Status Indicator Light (Berde: Normal na Power Supply Operation, Pula: Power Supply Fault)

20 – Lokal/Remote Control Switch

Rmag-emoteKontrolin ang Type

Mga Tagubilin sa Xingtongli Rectifier (2)

1 – Output Voltage Display Header (V)

2 – Audio-Visual Alarm (Opsyonal)

3 – Output Kasalukuyang Display Header (A)

4 – Smart Ammeter (Opsyonal)

5 – Soft Start Time Adjustment (0-100S) (Opsyonal)

6 – Power Supply Status Indicator (Berde: Power Supply Normal, Pula: Power Supply Fault)

7 – Power Output Adjustment Potentiometer

8 – Constant Current/Constant Voltage Conversion Switch, piliin ang operating mode, hindi pinapayagang lumipat sa pagitan ng pare-pareho ang kasalukuyang at pare-pareho ang boltahe sa panahon ng operasyon

9 – Pindutan ng I-pause para sa Time Relay (Katugma sa Time Relay)

10 – Power Output Switch (ON/OFF), kinokontrol ang operasyon ng power supply o standby

11 – I-reset ang Pindutan para sa Time Relay (Katugma sa Time Relay)

12 – Time Relay (User Opsyonal), para sa timing control

13 – Nakapirming Mounting Plate

 

Uri ng Pagbabaliktad ng Panlabas na Kontrol

 

1 – Output Voltage Display Header (V)

2 – Output Kasalukuyang Display Header (A)

3 – Manu-mano/Awtomatikong Pag-reversing Switch

4 – Constant Current/Constant Voltage Conversion Switch, hindi pinapayagang lumipat sa pagitan ng pare-parehong kasalukuyang at pare-parehong boltahe sa panahon ng operasyon

5 – Manual Forward/Manual Reverse Switch

6 – Power Output Adjustment Potentiometer

7 – Remote Control Aviation Socket

8 – Power Output Switch (ON/OFF), kinokontrol ang operasyon ng power supply o standby

9 – Start Button para sa Multi-stage Time Relay (Katugma sa Multi-stage Time Relay)

10 – Power Supply Status Indicator (Berde: Normal na Operasyon, Pula: Power Supply Fault)

11 – I-reset ang Button para sa Multi-stage Time Relay (Katugma sa Multi-stage Time Relay)

12 – Pag-reverse ng Multi-stage Time Relay, naka-time na reversing control

13 – Audio-Visual Alarm

14 – Nakapirming Mounting Plate